Standards
IEC 60502-1, UNE 21123-2
(Construction and tests)
CPR Regulation (EU) No 305/2011:
Reaction to fire (Eca)
IEC 60332-1-2, IEC 60332-3-24
(Fire and flame retardant (bunches))
LOW VOLTAGE DIRECTIVE: 2014/35/EU
RoHS compliant
Quality certificate





Technical characteristics & performances
-
Multicore
-
Solid conductor (class 1) mm2
-
Stranded conductor (class 2) mm2
-
Maximum service temperature: 90ºC / 250ºC
-
0,6/1 (1,2) kV C.A
-
Tensile forces
-
Mechanical protection
-
Low temperature resistance
-
Anti rodents
Fire performance
-
Eca (reaction to fire)
-
Flame retardant
-
Fire retardant
Uses and applications
-
Distribution networks
-
Industral use
-
Exterior lighting
-
Outdoor use
Packaging
-
Drum
Functional features
-
Technical designation:
RVMV 0,6/1 kV (SWA - steel wire armour cable)
-
Constructive description:
IEC 60502-1 & UNE 21123-2 (Construction and tests)
- CONDUCTOR:
Annealed copper conductor, class 1(s: 1,5/2,4 or 4 mm2) or class 2 (from 6 mm2 up to 300 mm2) based on International standard IEC 60228 / EN 60228.
- INSULATION:
Cross-linked polyethylene (XLPE) according to International standard IEC 60502-1
- ASSEMBLY OF CONDUCTORS:
In multicore cables, the cores are cabled helically.
- INNER SHEATH:
PVC type ST2 according to International standard IEC 60502-1.
- ARMOUR:
A single layer of galvanized steel wires armour in accordance with UNE 21123-2 / IEC 60502-1.
- OUTER SHEATH:
PVC type ST2 according to International standard IEC 60502-1.
Barrynax AR-Corona RVMV 0,6/1 kV is only multicore cable (2,3,4,5 cores / From 1,5 up to 150 mm2)
Identification of cores HD 308 S2:
2x - brown and blue
3x - brown, black and gray
3G - brown, blue and yellow / green
4x - brown, black, gray, blue
4G - brown, black, gray, yellow / green
5G - brown, black, gray, blue, yellow / green -
Rated voltage:
0.6/1 kV
-
Normal operation temperature:
90ºC
-
Short-circuit temperature (5 s max):
250ºC
-
Voltage test:
3,5 kV
-
Colour:
Black
-
Fire performance:
- Reaction to fire: Eca (EN 50575:2014+A1:2016)
For covered range (+ information), please check out "CPR/DoP" section in our website.
*The packaging labels of these cables include the CE marking according to the CPR Regulation ((UE) Nº 305/2011) articles 8 and 9.
Other performances:
- Flame retardant: EN 60332-1-2; IEC 60332-1-2 (H≤425 mm)
- Fire retardant: EN 60332-3-24; IEC 60332-3-24 (Cat. C). -
Type of installation:
Fixed
-
User´s guide:
It is specially indicated for its use in distribution networks in which there is a high risk of fire/explosion, mechanical aggressions or tensile stress.
For transport and distribution of electrical energy infixed facilities, protected or not. Adapted for inside and on the outside.
NOTE:
RVhMVh: Available with special sheath compound with mineral oils & liquid fuels resistance (acc. to UIC 895 OR) and with reduced halogen emissions (>15% HCl acc. to IEC 60754). Please, contact our Commercial Department for more information. -
Technical instructions:
.
-
Conductor:
Rigid
-
Halogen free:
No
-
Armoured cable:
Yes