North America Icon North America
Latin America Icon Latin America

Product Catalogue

You are in: Home | Catalogue | Afirenas RZ1MZ1-K
Back to product search

Afirenas RZ1MZ1-K

Standards

IEC 60502-1, UNE 21123-4
(Construction & tests)

Low voltage Directive (L.V.D.): 2014/35/UE

CPR REGULATION 305/2011/UE: 
Reaction to fire (Cca - s1b, d1, a1)

IEC 60332-3-24; EN 60332-3-24
Fire retardant

RoHS compliant.

Quality certificate

Certificate icon Low voltage Directive (LVD): 2014/35/EUCertificate icon CPR compliantCertificate icon RoHS

Technical characteristics & performances

  • Multicore Propiedad del cable: Multicore
  • Bunched conductor (class 5) mm2 Propiedad del cable: Bunched conductor (class 5) mm2
  • Maximum service temperature: 90ºC / 250ºC Propiedad del cable: Maximum service temperature: 90ºC / 250ºC
  • 0,6/1 (1,2) kV C.A Propiedad del cable: 0,6/1 (1,2) kV C.A
  • Tensile forces Propiedad del cable: Tensile forces
  • Mechanical protection Propiedad del cable: Mechanical protection
  • Oil resistance Propiedad del cable: Oil resistance
  • Low temperature resistance Propiedad del cable: Low temperature resistance
  • Anti rodents Propiedad del cable: Anti rodents

Fire performance

  • Cca-s1b,d1,a1 (reaction to fire) Propiedad del cable: Cca-s1b,d1,a1 (reaction to fire)
  • Flame retardant Propiedad del cable: Flame retardant
  • Fire retardant Propiedad del cable: Fire retardant
  • Low heat emission Propiedad del cable: Low heat emission
  • Low production of flaming droplets Propiedad del cable: Low production of flaming droplets
  • Low opacity & production of smoke Propiedad del cable: Low opacity & production of smoke
  • Low acidity & conductivity of the gases: pH<4,3 2,5 µS/mm Propiedad del cable: Low acidity & conductivity of the gases: pH<4,3 2,5 µS/mm
  • Halogen free Propiedad del cable: Halogen free
  • Low emission of toxic gases Propiedad del cable: Low emission of toxic gases

Uses and applications

  • Installations with risk of fire or explosion Propiedad del cable: Installations with risk of fire or explosion
  • BD2, BD3, BD4 (skyscrapers, tunnels…) Propiedad del cable: BD2, BD3, BD4 (skyscrapers, tunnels…)
  • Buildings receiving the public Propiedad del cable: Buildings receiving the public
  • Outdoor use Propiedad del cable: Outdoor use
  • Indoor use Propiedad del cable: Indoor use

Packaging

  • Drum Propiedad del cable: Drum


Functional features

  • Technical designation:
    RZ1MZ1-K(AS) 0,6/1 kV  (multicore cables)
  • Constructive description:
    IEC 60502-1, UNE 21123-4 (Construction and tests)

    LOW VOLTAGE DIRECTIVE: 2014/35 / EU
    RoHS compliant

    CONSTRUCTION DESCRIPTION:
    - CONDUCTOR:
    Flexible, annealed, plain copper conductor, class 5 based on standard IEC 60228.
    - INSULATION:
    Cross-linked polyethylene (XLPE) according to International standard IEC 60502-1
    - ASSEMBLY OF CONDUCTORS:
    In multicore cables, the cores are cabled helically.
    - INNER SHEATH:
    Extruded polyolefin type ST8 according to International standard IEC 60502-1.
    - ARMOUR:
    A single layer of galvanized steel wires armour acc. to IEC 60502-1 / UNE 21123-4.
    - OVERSHEATH:
    Extruded polyolefin type ST8 according to International standard IEC 60502-1.

    Identification of cores HD 308 S2:
    2x - brown and blue
    3x - brown, black and gray
    3G - brown, blue and yellow / green
    4x - brown, black, gray, blue
    4G - brown, black, gray, yellow / green
    5G - brown, black, gray, blue, yellow / green
  • Rated voltage:
    0.6/1 kV
  • Normal operation temperature:
    90ºC
  • Short-circuit temperature (5 s max):
    250ºC
  • Voltage test:
    3,5 kV
  • Colour:
    (OVERSHEATH) Green (black, under request)
  • Fire performance:
    Reaction to fire:  Cca-s1b, d1, a1 (EN 50575:2014+A1:2016)
       • EN 60332-1-2; IEC 60332-1 (H≤425 mm)  Flame retardant
       • EN 50399 (flame source: 20,5 kW) Fs ≤ 2 m  Fire retardant
       • Low heat generation: EN 50399 (flame source: 20,5 kW)
             - Total heat released: THR ≤ 30 MJ 
             - Maximum value of the heat released: Peak HRR ≤ 60 kW
             - Indication of heat increase: FIGRA ≤ 300 W/s
       • Low production and opacity of emitted smokes:
             - s1 (EN 50399):
                -Total smoke production: (TSP) ≤ 50 m2
                -Maximum value of smokes released : (Peak SPR) ≤ 0,25 m2/s
             - s1b: s1 and Transmittance > 60 % (UNE EN 61034-2; IEC 61034-2)
       • Low production of flaming droplets (EN 50399 - flame source:20,5 kW):
             - d1: No flaming droplets/particles persisting longer than 10' occurs within 1200'.
       • Low acidity and conductivity of the emitted gases:
             - a1: pH≥4,3 conductivity < 2,5 microS/mm (EN 60754-2; IEC 60754-2)

    For covered range (+ information), please check out "CPR/DoP" section in our website.
    *The packaging labels of these cables include the CE marking according to the CPR Regulation ((UE) Nº 305/2011) articles 8 and 9.


    Other performances:
    Fire retardant: UNE EN 60332-3-24 / IEC 60332-3-24 (cat.C)
    Halogen free. Low emission of toxic gases: UNE EN 60754-1 / IEC 60754-1
  • Type of installation:
    Fixed
  • User´s guide:
    Its use is recommended for installations where the cable is subject to risk of mechanical aggresion.
    It is specially indicated for its use in distribution networks, public concurrence places (airports, museums, malls, schools, hospitals, cinemas,...) and in general, whenever an important fire risk exists or where it´s required a low smoke emission and corrosive gases in case of fire. 

    Its special fire performance protects public health, fireman works and avoid any possible damage to electronic equipments.
  • Technical instructions:
       
  • Conductor:
    Flexible
  • Halogen free:
    Yes
  • Armoured cable:
    Yes

SEARCH